OPERATING
SPECS |
Std Duty O/L Ratings: |
110% for 60 seconds |
Heavy Duty O/L Ratings: |
150% for 60 seconds |
Servo Torque Ratings: |
Consult factory |
|
Output Frequency:
|
0 - 1000 Hz; V/Hz mode |
Switching
Frequency: |
0 - 350 Hz; closed loop vector mode |
| 0 - 120 Hz; sensorless vector mode |
| 2 kHz (standard default), adjustable
to
4
KHz** de-rating may apply; consult factory. Audibly silent switching
frequency pattern. |
Dynamic
Braking: |
Built-in DB switch and DB Resistor |
| Standard, 100% Torque rated (limited duty) |
| Option for external resistor |
Ambient Temperature: |
0°C to 40°C (32°F to 104°F) |
Product Enclosure: |
Rating IP21/NEMA 1 standard. IP52
and higher is special order |
Enclosure Rating |
Enclosure provides 15dB attenuation to
radiated emissions between 30-100MHz. |
Humidity |
Maximum 90% relative humidity at 40°C non-condensin |
Atmosphere |
Non flammable, non corrosive and dust free |
Climatic Conditions |
Class 3k3, as defined by EN50178 (1998) |
Vibration |
Test Fc of EN60068-2-6 |
STANDARDS |
Pollution Degree |
Pollution Degree ll (non-conductive pollution,
except for temporary condensation) |
Europe |
This product conforms with the Low Voltage
Directive 73/23/EEC with amendment 93/68/EEC, Article 13 and
Annex IIIusing EN50178 (1998) to show compliance. Meets EN61800-3
(2nd environment |
North America/ Canada |
Complies with the requirements of UL 508C |